Ade, R and Rehm, M (2020) Reaching for the stars: green construction cost premiums for Homestar certification. Construction Management and Economics, 38(06), 570–80.

Arashpour, M, Heidarpour, A, Akbar Nezhad, A, Hosseinifard, Z, Chileshe, N and Hosseini, R (2020) Performance-based control of variability and tolerance in off-site manufacture and assembly: optimization of penalty on poor production quality. Construction Management and Economics, 38(06), 502–14.

Hamilton, I G, Summerfield, A J, Steadman, J P, Stone, A and Davies, M (2010) Exploring energy integration between new and existing developments. Building Research & Information, 38(06), 609.

Hammad, A W, Grzybowska, H, Sutrisna, M, Akbarnezhad, A and Haddad, A (2020) A novel mathematical optimisation model for the scheduling of activities in modular construction factories. Construction Management and Economics, 38(06), 534–51.

Hassan, A and El-Rayes, K (2020) Quantifying the interruption impact of activity delays in non-serial repetitive construction projects. Construction Management and Economics, 38(06), 515–33.

Hernandez, P and Kenny, P (2010) Integrating occupant preference and life cycle energy evaluation: a simplified method. Building Research & Information, 38(06), 37.

Littlefair, P, Ortiz, J and Bhaumik, C D (2010) A simulation of solar shading control on UK office energy use. Building Research & Information, 38(06), 46.

Loosemore, M, Alkilani, S and Mathenge, R (2020) The risks of and barriers to social procurement in construction: a supply chain perspective. Construction Management and Economics, 38(06), 552–69.

Lucke, T and Beecham, S (2010) Aeration and gutter water levels in siphonic roof drainage systems. Building Research & Information, 38(06), 85.

  • Type: Journal Article
  • Keywords: aeration; gutter water levels; negative pressures; siphonic roof drainage
  • ISBN/ISSN: 0961-3218
  • URL: https://doi.org/10.1080/09613218.2010.503050
  • Abstract:
    An investigation is presented into how negative system pressures, the degree of aeration, and gutter water levels are affected by the number of outlets in a siphonic roof drainage system. The experimental results show that system pressures decrease if outlets are blocked. It is also shown that the depth of water above an outlet is strongly influenced by the negative pressure acting at the outlet. As the suction effect at the outlet increases, due to lower system pressures, more water and air will be drawn into the outlets and this will result in a corresponding increase in overall gutter water depth. The results also show that there is often built-in redundancy in multiple outlet siphonic systems experiencing lower-intensity rainfall events, and if one or two outlets were blocked, the system would still operate satisfactorily. A new outlet suppressor was trialled and this was shown to reduce gutter water levels by up to 58% at some positions in the gutter.

Pink, S, Tutt, D, Dainty, A and Gibb, A (2010) Ethnographic methodologies for construction research: knowing, practice and interventions. Building Research & Information, 38(06), 647-659.

Steinhardt, D, Manley, K, Bildsten, L and Widen, K (2020) The structure of emergent prefabricated housing industries: a comparative case study of Australia and Sweden. Construction Management and Economics, 38(06), 483–501.

Tenpierik, M J and Cauberg, J J M (2010) Encapsulated vacuum insulation panels: theoretical thermal optimization. Building Research & Information, 38(06), 9.

Thomas, L E (2010) Evaluating design strategies, performance and occupant satisfaction: a low carbon office refurbishment. Building Research & Information, 38(06), 24.